How NOT to wire a (UK) mains plug: Difference between revisions

No edit summary
Line 1: Line 1:
This page illustrates a number of different faults in wiring a mains plug, , all of them dangerous.
This page illustrates a number of different faults in wiring a mains plug, all of them potentially dangerous.


==Summary==
==Summary==
Wiring a mains plug is not hard, and most of the ptfalls are easy to recognise.
Wiring a mains plug is not hard, and most of the pitfalls are easy to recognise.
 
Retaining the basic structure, replace all the text of this page with your own content.


===Safety===
===Safety===

Revision as of 20:30, 26 October 2022

This page illustrates a number of different faults in wiring a mains plug, all of them potentially dangerous.

Summary

Wiring a mains plug is not hard, and most of the pitfalls are easy to recognise.

Safety

Warning03.png
A badly or incorrectly wired mains plug can create a risk of electric shock or fire.

How NOT to do it!

Error creating thumbnail: /bin/bash: line 1: /usr/bin/convert: No such file or directory Error code: 127

See how many faults you can spot before revealing the answers by clicking the down-arrorws on the right.

Fault 1:

The plastic shell of the plug is broken. There must be no physical damage or signs of overheating.

Fault 2:

There is a piece of wire in place of the fuse. The plug must contain a suitably rated fuse, otherwise in the event of a fault, a dangerously large current may flow before one of the house fuses blows.

Fault 3:

The live (brown) and blue (neutral) wires are the wrong way round. The brown must go to the screw terminal next to the fuse and the blue to the screw terminal opposite.

Fault 5:

There is no screw in the earth screw terminal (with the green/yellow wire). All screws must be tight, otherwise the pug may overheat. In addition, the lack of a proper earth connection could be highly dangerous.

Fault 6:

The insulation on brown wire has been stripped back too far, leaving exposed copper.

Fault 7:

The blue wire has loose whiskers of wire which could cause a short circuit.

Fault 8:

The cable clamp is clamping the inner wires, causing strain on the insulation. The outer sheath of the cable must be firmly clamped to prevent any strain on the connections or the inner (brown, blue and green/yellow) wires.