How NOT to wire a (UK) mains plug

This page illustrates a number of different faults in wiring a mains plug, all of them potentially dangerous.

Summary

Wiring a mains plug is not hard, and most of the pitfalls are easy to recognise.

Safety

Warning03.png
A badly or incorrectly wired mains plug can create a risk of electric shock or fire.

How NOT to do it!

Error creating thumbnail: /bin/bash: line 1: /usr/bin/convert: No such file or directory Error code: 127

See how many faults you can spot before revealing the answers by clicking the down-arrows on the right.

Fault 1:
Error creating thumbnail: File missing
The plastic shell of the plug is broken. There must be no physical damage or signs of overheating.
Fault 2:
Error creating thumbnail: File missing
There is a piece of wire in place of the fuse. The plug must contain a suitably rated fuse, otherwise in the event of a fault, a dangerously large current may flow before one of the house fuses blows.
Fault 3:
Error creating thumbnail: File missing
The live (brown) and blue (neutral) wires are the wrong way round. The brown must go to the screw terminal next to the fuse and the blue to the screw terminal opposite.
Fault 4:
Error creating thumbnail: File missing
There is no screw in the earth screw terminal (with the green/yellow wire). All screws must be tight, otherwise the plug may overheat. In addition, the lack of a proper earth connection could be highly dangerous.
Fault 5:
Error creating thumbnail: File missing
The insulation on brown wire has been stripped back too far, leaving exposed copper.
Fault 6:
Error creating thumbnail: File missing
The blue wire has loose whiskers of wire which could cause a short circuit.
Fault 7:
Error creating thumbnail: File missing
The cable clamp is clamping the inner wires, causing strain on the insulation. The outer sheath of the cable must be firmly clamped to prevent any strain on the connections or the inner (brown, blue and green/yellow) wires.
Fault 8:
Error creating thumbnail: File missing
Look carefully: in removing the outer sheath, the insulation on the brown wire has been nicked. The copper of the live wire is exposed.