Most small fan heaters will have a thermal fuse. This is a self-destructive fuse, usually on the other side of the heating element/s. These fuses will go open circuit once a certain temperature threshold is reached, preventing fires when heaters are inadvertently covered with clothes etc.


These fuses shouldn't be soldered, as the temperature will cause them to go open circuit! Instead, most are riveted into the circuit. To replace, cut the axial leads of the blown fuse, then work the leads out from under the rivets. On the replacement fuse, bend the leads under the rivets using a small screwdriver and trim any excess. Make sure the replacement fuse is the correct temperature and current rating as the factory original.


[[Category:Fixing]]
[[Category:Fixing]]

Revision as of 02:24, 7 September 2020

This is currently a skeleton page. Please help by adding your contributions either here or in the associated Discussion page.

This page will cover fans of all types and fan heaters.

Summary

Fans come in a variety of forms from desk fans, floor-standing fans and ceiling fans. Fan heaters are similar, just having an electrical heating element in the air flow.

Safety

Warning03.png
As with all mains electrical devices, dangerous voltages may be exposed when opened.

Main section

Most small fan heaters will have a thermal fuse. This is a self-destructive fuse, usually on the other side of the heating element/s. These fuses will go open circuit once a certain temperature threshold is reached, preventing fires when heaters are inadvertently covered with clothes etc.

These fuses shouldn't be soldered, as the temperature will cause them to go open circuit! Instead, most are riveted into the circuit. To replace, cut the axial leads of the blown fuse, then work the leads out from under the rivets. On the replacement fuse, bend the leads under the rivets using a small screwdriver and trim any excess. Make sure the replacement fuse is the correct temperature and current rating as the factory original.